NACA 0012 Pressure Distribution & Stall

How can pressure distribution be used to identify the stall angle of a NACA 0012 aerofoil under subsonic flow?

StatuscompletedDatesJune–August 2024RoleAuthor and analystAffiliationIndependent analysis · University of Nottingham wind-tunnel dataset
1

Context & question

How can pressure distribution be used to identify the stall angle of a NACA 0012 aerofoil under subsonic flow?

Converted pressure readings from 20 surface taps across 11 angles of attack into chordwise pressure distributions and an integrated lift curve, then compared the measured stall behaviour with published low-speed NACA 0012 data.

Surface taps
20
10 upper · 10 lower
Angles tested
11
-2° to 18° · 2° steps
Freestream velocity
20 m/s
Air density
1.25 kg/m³
Chord
150 mm
Dynamic pressure
0.25 kPa
Reynolds number
≈23,000
Measured stall
14°
Cₗ,max = 1.304
2

My contribution

  • Converted each tap's measured static pressure into pressure coefficient using the report's calculated dynamic pressure of 0.25 kPa.
  • Normalized every tap position by the 150 mm chord and plotted upper- and lower-surface Cₚ distributions across x/c for each angle of attack.
  • Integrated the lower-minus-upper pressure-coefficient difference across the chord to calculate Cₗ at all eleven angles.
  • Located the experimental Cₗ peak, traced the post-stall decline, and compared the curve with low-speed reference data at Re = 48,000 and 88,000.
  • Authored the complete ten-page technical report in LaTeX, including methodology, quantitative analysis, limitations, figures, and references.
3

Outcome

The integrated pressure data produced a maximum lift coefficient of 1.304 at 14°, identifying 14° as the measured stall angle for this dataset. Cₗ then fell at 16° and 18°. The comparison dataset at Re = 48,000 stalled at approximately 13.5°; the report attributes the 0.5° difference primarily to the lower experimental Reynolds number of approximately 23,000.

4

Excerpts

Three report figures trace the analysis from pressure distribution to measured lift and theory comparison. Select any graph to enlarge it.

Figure 6 · Pressure distribution at 8°

Representative pre-stall Cₚ distribution showing upper-surface suction near the leading edge.

Upper and lower surface pressure coefficient plotted against normalized chord position at 8 degrees angle of attack
Figure 7 · Experimental lift curve

The integrated lift curve peaks at 14° with Cₗ,max = 1.304.

Experimental coefficient of lift plotted against angle of attack, peaking at 14 degrees before declining
Figure 9 · Experiment versus theory

The measured trend agrees with the references but stalls slightly later.

Experimental lift curve compared with theory data at Reynolds numbers 48,000 and 88,000
5

Full report

Read the complete technical report, including the methodology, figures, analysis, and references.