NACA 0012 Pressure Distribution & Stall
How can pressure distribution be used to identify the stall angle of a NACA 0012 aerofoil under subsonic flow?
Context & question
How can pressure distribution be used to identify the stall angle of a NACA 0012 aerofoil under subsonic flow?
Converted pressure readings from 20 surface taps across 11 angles of attack into chordwise pressure distributions and an integrated lift curve, then compared the measured stall behaviour with published low-speed NACA 0012 data.
- Surface taps
- 20 10 upper · 10 lower
- Angles tested
- 11 -2° to 18° · 2° steps
- Freestream velocity
- 20 m/s
- Air density
- 1.25 kg/m³
- Chord
- 150 mm
- Dynamic pressure
- 0.25 kPa
- Reynolds number
- ≈23,000
- Measured stall
- 14° Cₗ,max = 1.304
My contribution
- Converted each tap's measured static pressure into pressure coefficient using the report's calculated dynamic pressure of 0.25 kPa.
- Normalized every tap position by the 150 mm chord and plotted upper- and lower-surface Cₚ distributions across x/c for each angle of attack.
- Integrated the lower-minus-upper pressure-coefficient difference across the chord to calculate Cₗ at all eleven angles.
- Located the experimental Cₗ peak, traced the post-stall decline, and compared the curve with low-speed reference data at Re = 48,000 and 88,000.
- Authored the complete ten-page technical report in LaTeX, including methodology, quantitative analysis, limitations, figures, and references.
Outcome
The integrated pressure data produced a maximum lift coefficient of 1.304 at 14°, identifying 14° as the measured stall angle for this dataset. Cₗ then fell at 16° and 18°. The comparison dataset at Re = 48,000 stalled at approximately 13.5°; the report attributes the 0.5° difference primarily to the lower experimental Reynolds number of approximately 23,000.
Excerpts
Three report figures trace the analysis from pressure distribution to measured lift and theory comparison. Select any graph to enlarge it.
Representative pre-stall Cₚ distribution showing upper-surface suction near the leading edge.
The integrated lift curve peaks at 14° with Cₗ,max = 1.304.
The measured trend agrees with the references but stalls slightly later.
Full report
Read the complete technical report, including the methodology, figures, analysis, and references.